Péppin' Lê Pew Logo

Péppin' Lê Pew

The Ultimate Peptide Reconstitution Calculator

This calculator simplifies peptide reconstitution by determining the precise amount of BAC water needed to achieve clean, round numbers of units per dose. No more mental math or imprecise measurements!

mg
vials
mg
mg/ml
units
ml
ml
doses
doses

Reconstitution Instructions

Summary:
  • Number of vials: X
  • Peptide per vial: X mg
  • Total BAC Water: X ml
  • Final Concentration: X mg/ml
  • Total peptide in final cartridge: X mg

Gather materials

  • 3 × ⅝” needles
  • 1 × 1 ½” needle
  • sterile alcohol wipes
  • 1 × 3 ml syringe
  • 1 × sterile 0.22μm filter
  • X peptide vials containing X mg each
  • Target concentration: X mg/ml
  • Total BAC water: X ml, plus some extra for purging and flushing
  • 1 × sterile empty cartridge/vial
  • 1 × pen needle
This technique has the following benefits:
  • ✅ fully purges filters of any size. No need to think about hold-back volume
  • ✅ keeps the BAC vial as uncontaminated as possible
  • ✅ prevents contamination of the cartridge
  1. Sanitize everything with 70% IPA
  2. Wipe down the cartridge and vial tops with sterile wipes
  3. Draw up X ml + 0.3 ml = X ml of BAC, or more
  4. Attach filter and ⅝” needle to BAC. Purge all air out of filter and needle
  5. Insert the needle + filter into the cart. Leave this needle + filter in the cart until the entire process is complete
  6. Remove the syringe (with all remaining BAC) from the filter, leaving the filter attached to the cart
  7. Attach a new 1 ½” needle
  8. Purge so there is X ml left in the syringe. Note: we’re reserving 0.5 ml for the final filter flush
  9. Split that X ml evenly between the peptide vials. That’s approximately X ml in each vial. The syringe should now be empty
  10. Cap the needle. Swirl the vials gently and wait 30 minutes, or at least 10 minutes more than you think you should (this allows microsocopic particles to dissolve)
  11. Uncap the needle and draw up the X ml of dissolved peptide solution from all the vials
  12. Remove the needle and discard it
  13. Get your ⅝” vent needle ready
  14. Attach the syringe to the filter/cart
  15. Gently press about 0.5 ml into the cart to create slight positive pressure. Do not over-pressurize or you risk blowing the plug out the bottom of the cartridge. The amount is not critical.
  16. Insert a ⅝” needle as a vent into the cart. Doing it in this order minimizes contamination risk; internal pressure keeps airflow one direction in the vent needle
  17. Finish injecting the rest of the peptide solution into the cart. Venting prevents excess pressure buildup
  18. We are still 0.5 ml short. Using a new ⅝” needle (never reuse a needle in the BAC vial), draw up 0.5 ml of BAC water. Disconnect that needle and discard it, reattach the syringe to the filter, and push the last 0.5 ml through to flush the filter
  19. Remove the vent needle and the filter needle
  20. Attach a pen needle and purge all air from the cart
  21. Detach the pen needle and discard. You're ready to go!

Label Generator

Tip: Using a shortened URL creates a simpler QR code that's easier to print clearly on small labels.

Labels (Click to Open)

Reconstituted Vials

QR Code

Data Matrix

Un-reconstituted Vials

QR Code

Data Matrix